Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8669071
- Product Categories
- Friendly Links
Information Name: | Supply of high-performance liquid chromatography Prominence LC-20A |
Published: | 2011-12-16 |
Validity: | 900 |
Specifications: | Prominence LC-20A |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Product Information Today, in all walks of life, to survive an increasingly competitive, regulatory intervention, IT technology quickly spread, and so on, which greatly changed the business environment. In this context, can be used for research and development, quality management, environmental monitoring and many other applications of high-performance liquid chromatography, customer requests and issues facing diverse. In order to quickly meet the diverse needs of customers, Shimadzu has developed into the overall strength of high-performance liquid chromatography - "Prominence". Enrich the basic performance, while the corresponding network requirements to establish a high degree of integrated management systems, unified management of data and devices, to achieve high efficiency of the analysis. Shimadzu Prominence HPLC will be the network's new logo Features: Network - the perfect solution for analysis of workers High performance - Easy to meet stringent customer requirements for equipment Automation - high efficiency and high reliability to win the trust of customers The main parameters: System controller Prominence CBM-20A/20Alite >> CBM-20A The unit can be connected: the infusion of up to 4 units, 1 unit autosampler, column oven 1 set, 2 sets up the detector, sub-collector a distillation units, up to 2 auxiliary controller Connection units: 8 (may be increased to 12) Data buffer: approximately 24 hours 1 analysis (sampling rate of 500ms, the only LCsolution use) >> CBM-20Alite The unit can be connected: the infusion of up to 4 units, autosampler (SIL-10AF/10AP/10A than) 1, oven 1 set, 2 sets up the detector, the secondary controller up to 2 Connect unit: 5 Data buffer: approximately 24 hours 1 analysis (sampling rate of 500ms, the only LCsolution use) Infusion unit Prominence LC-20AD/20AT/20AB >> LC-20AD Infusion methods: parallel double plunger Plunger Capacity: 10μL Maximum discharge pressure: 40MPa Flow Range: 0.0001mL/min-10.0000mL/min Flow Accuracy: 1% or 2μL / min which is greater or less Flow precision: 0.06% RSD or 0.02minSD, which is greater or less >> LC-20AT Infusion mode: dual piston in series Plunger Capacity: main pump head 47μL, 23μL, vice pump head Maximum discharge pressure: 40MPa Flow Range: 0.001mL/min-10.000mL/min Flow Accuracy: 2% or greater within one 2μL/min Flow precision: 0.06% RSD or 0.02minSD, which is greater or less >> LC-20AB Infusion methods: parallel double plunger (Type 2) Plunger Capacity: 10μL Maximum discharge pressure: 40MPa Flow Range: 0.0001mL/min-10.0000mL/min Flow Accuracy: 1% or 2μL / min which is greater or less Flow precision: 0.06% RSD or 0.02minSD, which is greater or less [Infusion unit gradient system] >> LC-20AB Gradient method: high-pressure mixing Mixed solvents: 2 liquid >> LC-20AD/20AT High GE specifications Gradient method: high-pressure mixing Mixed solvents: 2 liquid solution or 3 >> LC-20AD/20AT low-GE specifications Gradient method: low-voltage mixed Mixed solvents: up to 4 fluid UV-Vis detector >> Prominence SPD-20A/20AV UV-VIS detector SPD-20A/SPD-20AV Light Source: SPD-20A D2 lamp, SPD-20AV D2 lamp, W lamp Wavelength range: SPD-20A 190nm-700nm, SPD-20AV 190nm-900nm Wavelength accuracy: 1nm the following Wavelength accuracy: 0.1nm the following Noise: ± 0.25 × 10-5AU Drift: ± 0.5 × 10-4AU / h Linearity:> 2.5AU Function: 190nm-370nm or 371nm or more dual-wavelength detection, the ratio chromatogram output, wavelength scanning, time program >> Prominence SPD-M20A PDA detector SPD-M20A Source: D2 lamp, W lamp Diode element: 512 Wavelength range: 190nm-800nm Wavelength accuracy: 1nm the following Wavelength accuracy: 0.1nm the following Noise: ± 0.3 × 10-5AU Drift: 0.5 × 10-3AU / h Linearity:> 2.0AU Function: the output contour, spectral search, the maximum output Autosampler Prominence SIL-20A/20AC Injection mode: full amount of injection, injection volume variable type Injection volume setting range: 0.1μL-100μL (standard), 1μL -2,000 μL (optional) Number of sample processing: 175 (1mL sample bottle) 105 (1.5mL sample bottle) SIL-20AC 70 (1.5mL sample bottle) 50 (4mL sample bottle) 192 (96 - hole MTP 2 blocks) 768 (384 - hole MTP 2 blocks) In the above specifications can be used outside of the other 1.5mL sample bottle 10 Injection volume accuracy: 1% Injection volume precision: 0.2% RSD The following Cross-contamination: 0.0025% typical following (naphthalene, chlorhexidine) Repeated number of injections: up to 30 / 1 sample Needle cleaning: any set in the sample before and after Sample cooler: SIL-20A without SIL-20AC module cooling and heating mode, and in addition to wave function 4 ℃ -40 ℃ Sample frame switch >> Switch C sample holder Applicable to board: 96 MTP, 96-hole DWP, 384 bore MTP, 384 holes DWP, 1.5mL vials (54) Board processing blocks: 12P Sample cooler: cooling heating module, and in addition to wave function 4 ℃ -40 ℃ Oven Prominence CTO-20A/20AC Thermostat: forced air circulation type Cooling: CTO-20A-free, CTO-20AC e cooled Temperature control accuracy: 0.1 ℃ or less (typical value 0.04 ℃ or less) Temperature control range: CTO-20A (room temperature +10) ℃ -85 ℃, CTO-20AC (room temperature, -10) ℃ -85 ℃ Shelter space: W220 × H365 × D95mm Accommodates equipment: manual injector 2, gradient mixer, high-pressure flow path switching valve 2, etc. Timing program: linear temperature program Safety measures: solvent sensor, thermal fuse, upper temperature limit |
Admin>>>
You are the 16501 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Rui Sheng Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 16501 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Rui Sheng Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility